Work orders / WO-2026-01122
P4 WO-2026-01122
Preventive work order, Verified. At City Hall Public Lot.
Response
- Priority
- P4, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Sep 7, 10:00 PDT
- Response due
- Sep 21, 10:00 PDT
- Planned
- Sep 16, 09:50 PDT
- On site
- Sep 16, 09:55 PDT
- Completed
- Sep 16, 12:09 PDT
- Verified
- Sep 16, 13:39 PDT
Who and where
- Site
- City Hall Public Lot TW-BEL-003
- Technician
- Jamal Freeman, Bellevue
- Contact
- +1-425-555-0274, jamal.freeman@example.com
- High voltage cert
- Yes, valid until Nov 30, 2026
- Charge points
- TW-BEL003-CP1
Notes
Yearly preventive inspection of TW-BEL003-CP1.
Faults answered
This work order answers no fault (a preventive visit, or not linked yet).
Service visits
Sep 16, 09:55 PDT to 12:09 PDT
Jamal Freeman
- Findings
- Preventive inspection: one worn part found, cabinet otherwise in good order.
- Work done
- Replaced the j1772 Type 1 cable 32A 18ft (NCW-CA-J17); cleaned the filters and torque-checked the terminals.
Parts fitted
| Part | Qty | Reason | From | Fitted |
|---|---|---|---|---|
| NCW-CA-J17 J1772 Type 1 cable 32A 18ft | 1 | Preventive | VanStock | Sep 16, 10:45 PDT |