Work orders / WO-2026-01142
P3 WO-2026-01142
Corrective work order, Verified. At Westlake Plaza Chargers.
Response
- Priority
- P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Nov 5, 10:47 PST
- Response due
- Nov 12, 10:46 PST
- Planned
- Nov 11, 10:36 PST
- On site
- Nov 11, 10:46 PST
- Completed
- Nov 11, 13:27 PST
- Verified
- Nov 11, 14:57 PST
Who and where
- Site
- Westlake Plaza Chargers TW-SEA-002
- Technician
- Danielle Ortiz, Seattle
- Contact
- +1-206-555-0218, danielle.ortiz@example.com
- High voltage cert
- Yes, valid until Jan 15, 2027
- Charge points
- TW-SEA002-CP1
Notes
ReaderFailure on TW-SEA002-CP1. Card reader does not respond; drivers cannot start a session with a card.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0941
ReaderFailure, Closed |
Medium | 16 d 3 h | – | Nov 5, 10:11 PST | Driver | No work order |
Service visits
Nov 11, 10:46 PST to 13:27 PST
Danielle Ortiz
- Findings
- Reader module dead; the ribbon cable and the supply are intact.
- Work done
- Replaced the cooling fan 92mm (CEV-FAN-092); card and app starts tested.
Parts fitted
| Part | Qty | Reason | From | Fitted |
|---|---|---|---|---|
| CEV-FAN-092 Cooling fan 92mm | 1 | Repair | VanStock | Nov 11, 11:41 PST |