Work orders / WO-2026-01144
P3 WO-2026-01144
Corrective work order, Verified. At Proctor District Lot.
Response
- Priority
- P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Nov 6, 10:49 PST
- Response due
- Nov 13, 10:48 PST
- Planned
- Nov 10, 10:38 PST
- On site
- Nov 10, 10:48 PST
- Completed
- Nov 10, 12:55 PST
- Verified
- Nov 10, 14:25 PST
Who and where
- Site
- Proctor District Lot TW-TAC-003
- Technician
- Darnell Rhodes, Tacoma
- Contact
- +1-253-555-0316, darnell.rhodes@example.com
- High voltage cert
- Yes, valid until Oct 15, 2026
- Charge points
- TW-TAC003-CP1
Notes
EVCommunicationError on TW-TAC003-CP1. Communication with the vehicle lost during the handshake.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0943
EVCommunicationError, Closed |
Low | 15 d 3 h | – | Nov 6, 09:47 PST | Driver | No work order |
Service visits
Nov 10, 10:48 PST to 12:55 PST
Darnell Rhodes
- Findings
- Signal pins in the plug worn; contact intermittent when the cable is moved.
- Work done
- Reseated and secured the affected assembly, restarted the charge point; handshake tested with two vehicles.
Parts fitted
No part fitted under this work order.