Demo data. These are example records in the Tidewire model, not live data from the charging backend.
Live updates on Data as of 13:38:41 PST

Work orders / WO-2026-01144

P3 WO-2026-01144

Corrective work order, Verified. At Proctor District Lot.

Response

Priority
P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Nov 6, 10:49 PST
Response due
Nov 13, 10:48 PST
Planned
Nov 10, 10:38 PST
On site
Nov 10, 10:48 PST
Completed
Nov 10, 12:55 PST
Verified
Nov 10, 14:25 PST

Who and where

Site
Proctor District Lot TW-TAC-003
Technician
Darnell Rhodes, Tacoma
Contact
+1-253-555-0316, darnell.rhodes@example.com
High voltage cert
Yes, valid until Oct 15, 2026
Charge points
TW-TAC003-CP1

Notes

EVCommunicationError on TW-TAC003-CP1. Communication with the vehicle lost during the handshake.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0943
EVCommunicationError, Closed
Low 15 d 3 h–
Nov 6, 09:47 PST Driver No work order

Service visits

Nov 10, 10:48 PST to 12:55 PST Darnell Rhodes
Findings
Signal pins in the plug worn; contact intermittent when the cable is moved.
Work done
Reseated and secured the affected assembly, restarted the charge point; handshake tested with two vehicles.

Parts fitted

No part fitted under this work order.

The connection to the dashboard was interrupted. Reload