Demo data. These are example records in the Tidewire model, not live data from the charging backend.
Live updates on Data as of 13:38:41 PST

Work orders / WO-2026-01143

P1 WO-2026-01143

Corrective work order, Verified. At South D Street Depot.

Response

Priority
P1, around-the-clock response
Created
Nov 5, 14:35 PST
Response due
Nov 5, 18:35 PST
Planned
Nov 5, 16:20 PST
On site
Nov 5, 16:30 PST
Completed
Nov 5, 18:20 PST
Verified
Nov 5, 19:50 PST

Who and where

Site
South D Street Depot TW-TAC-012
Technician
Megan O'Connell, Tacoma
Contact
+1-253-555-0305, megan.oconnell@example.com
High voltage cert
Yes, valid until Apr 12, 2027
Charge points
TW-TAC012-CP1

Notes

PowerSwitchFailure on TW-TAC012-CP1. Main contactor does not close; no output on any connector.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0942
PowerSwitchFailure, Closed
Critical 15 d 23 h–
Nov 5, 13:40 PST ChargePoint No work order

Service visits

Nov 5, 16:30 PST to 18:20 PST Megan O'Connell
Findings
Main contactor contacts welded; coil resistance out of range.
Work done
Replaced the 24V control relay (OLY-RLY-24); torque checked on the power terminals and a full-power session completed.
Warranty claim
VG-WC-26-0914

Parts fitted

PartQtyReasonFromFitted
OLY-RLY-24
24V control relay
1RepairVanStockNov 5, 17:25 PST