Work orders / WO-2026-01139
P2 WO-2026-01139
Corrective work order, Verified. At Northgate I-5 Fast Stop.
Response
- Priority
- P2, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Nov 3, 09:21 PST
- Response due
- Nov 5, 11:20 PST
- Planned
- Nov 3, 13:11 PST
- On site
- Nov 3, 13:21 PST
- Completed
- Nov 3, 16:44 PST
- Verified
- Nov 3, 18:14 PST
Who and where
- Site
- Northgate I-5 Fast Stop TW-SEA-007
- Technician
- Danielle Ortiz, Seattle
- Contact
- +1-206-555-0218, danielle.ortiz@example.com
- High voltage cert
- Yes, valid until Jan 15, 2027
- Charge points
- TW-SEA007-CP1
Notes
OverCurrentFailure on TW-SEA007-CP1. Output over-current trip at the start of a session.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0938
OverCurrentFailure, Closed |
High | 18 d 5 h | – | Nov 3, 08:33 PST | ChargePoint | No work order |
Service visits
Nov 3, 13:21 PST to 16:44 PST
Danielle Ortiz
- Findings
- One power stage draws unbalanced current and trips the protection.
- Work done
- Reseated and secured the affected assembly, restarted the charge point; load test passed at rated current.
Parts fitted
No part fitted under this work order.