Work orders / WO-2026-01135

P2 WO-2026-01135

Corrective work order, Verified. At South Tacoma Way Plaza.

Response

Priority
P2, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Oct 27, 10:07 PDT
Response due
Oct 29, 12:07 PDT
Planned
Oct 27, 12:57 PDT
On site
Oct 27, 13:07 PDT
Completed
Oct 27, 16:13 PDT
Verified
Oct 27, 17:43 PDT

Who and where

Site
South Tacoma Way Plaza TW-TAC-011
Technician
Darnell Rhodes, Tacoma
Contact
+1-253-555-0316, darnell.rhodes@example.com
High voltage cert
Yes, valid until Oct 15, 2026
Charge points
TW-TAC011-CP1

Notes

GroundFailure on TW-TAC011-CP1. Ground fault detected during pre-charge; sessions abort before power flows.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0932
GroundFailure, Closed
High 25 d 5 h–
Oct 27, 09:26 PDT ChargePoint No work order
FLT-26-0933
InternalError, Closed
Low 25 d 5 h–
Oct 27, 09:38 PDT ChargePoint No work order

Service visits

Oct 27, 13:07 PDT to 16:13 PDT Darnell Rhodes
Findings
Insulation resistance low on the output; the ground fault interrupter trips under load.
Work done
Replaced the ground fault interrupter module (RRE-GF-020); insulation test passed and three test sessions completed.
Warranty claim
VG-WC-26-0913

Parts fitted

PartQtyReasonFromFitted
RRE-GF-020
Ground fault interrupter module
1RepairVanStockOct 27, 14:02 PDT