P3 WO-2026-01134

Corrective work order, Verified. At Lincoln Plaza Chargers.

Response

Priority
P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Oct 21, 11:33 PDT
Response due
Oct 28, 11:32 PDT
Planned
Oct 27, 11:22 PDT
On site
Oct 27, 11:32 PDT
Completed
Oct 27, 14:21 PDT
Verified
Oct 27, 15:51 PDT

Who and where

Site
Lincoln Plaza Chargers TW-BEL-002
Technician
Jamal Freeman, Bellevue
Contact
+1-425-555-0274, jamal.freeman@example.com
High voltage cert
Yes, valid until Nov 30, 2026
Charge points
TW-BEL002-CP1

Notes

WeakSignal on TW-BEL002-CP1. Backend connection drops several times an hour.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0931
WeakSignal, Closed
Low 31 d 4 h–
Oct 21, 10:19 PDT ChargePoint No work order

Service visits

Oct 27, 11:32 PDT to 14:21 PDT Jamal Freeman
Findings
Modem antenna lead damaged where it passes the door hinge.
Work done
Reseated and secured the affected assembly, restarted the charge point; signal strength steady and the connection held for an hour.

Parts fitted

No part fitted under this work order.