Work orders / WO-2026-01131
P2 WO-2026-01131
Corrective work order, Verified. At Harrison Campus Stop.
Response
- Priority
- P2, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Oct 14, 10:19 PDT
- Response due
- Oct 16, 12:18 PDT
- Planned
- Oct 14, 17:09 PDT
- On site
- Oct 14, 17:19 PDT
- Completed
- Oct 14, 19:51 PDT
- Verified
- Oct 14, 21:21 PDT
Who and where
- Site
- Harrison Campus Stop TW-SEA-004
- Technician
- Trevor Hanson, Seattle
- Contact
- +1-206-555-0236, trevor.hanson@example.com
- High voltage cert
- Yes, valid until Dec 5, 2026
- Charge points
- TW-SEA004-CP1
Notes
PowerMeterFailure on TW-SEA004-CP1. Energy meter values missing from the transactions.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0929
PowerMeterFailure, Closed |
Medium | 38 d 5 h | – | Oct 14, 09:12 PDT | ChargePoint | No work order |
Service visits
Oct 14, 17:19 PDT to 19:51 PDT
Trevor Hanson
- Findings
- Meter communication lost; a connector on the controller harness had worked loose.
- Work done
- Reseated and secured the affected assembly, restarted the charge point; meter values confirmed against a reference session.
Parts fitted
No part fitted under this work order.