P2 WO-2026-01131

Corrective work order, Verified. At Harrison Campus Stop.

Response

Priority
P2, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Oct 14, 10:19 PDT
Response due
Oct 16, 12:18 PDT
Planned
Oct 14, 17:09 PDT
On site
Oct 14, 17:19 PDT
Completed
Oct 14, 19:51 PDT
Verified
Oct 14, 21:21 PDT

Who and where

Site
Harrison Campus Stop TW-SEA-004
Technician
Trevor Hanson, Seattle
Contact
+1-206-555-0236, trevor.hanson@example.com
High voltage cert
Yes, valid until Dec 5, 2026
Charge points
TW-SEA004-CP1

Notes

PowerMeterFailure on TW-SEA004-CP1. Energy meter values missing from the transactions.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0929
PowerMeterFailure, Closed
Medium 38 d 5 h–
Oct 14, 09:12 PDT ChargePoint No work order

Service visits

Oct 14, 17:19 PDT to 19:51 PDT Trevor Hanson
Findings
Meter communication lost; a connector on the controller harness had worked loose.
Work done
Reseated and secured the affected assembly, restarted the charge point; meter values confirmed against a reference session.

Parts fitted

No part fitted under this work order.