Work orders / WO-2026-01128

P1 WO-2026-01128

Corrective work order, Verified. At Pacific Highway I-5 Stop.

Response

Priority
P1, around-the-clock response
Created
Oct 6, 09:05 PDT
Response due
Oct 6, 13:05 PDT
Planned
Oct 6, 10:45 PDT
On site
Oct 6, 10:55 PDT
Completed
Oct 6, 13:10 PDT
Verified
Oct 6, 14:40 PDT

Who and where

Site
Pacific Highway I-5 Stop TW-TAC-010
Technician
Darnell Rhodes, Tacoma
Contact
+1-253-555-0316, darnell.rhodes@example.com
High voltage cert
Yes, valid until Oct 15, 2026
Charge points
TW-TAC010-CP1

Notes

PowerSwitchFailure on TW-TAC010-CP1. Main contactor does not close; no output on any connector.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0926
PowerSwitchFailure, Closed
Critical 46 d 6 h–
Oct 6, 08:05 PDT ChargePoint No work order

Service visits

Oct 6, 10:55 PDT to 13:10 PDT Darnell Rhodes
Findings
Main contactor contacts welded; coil resistance out of range.
Work done
Replaced the safety contactor relay (OLY-RLY-48); torque checked on the power terminals and a full-power session completed.
Warranty claim
VG-WC-26-0912

Parts fitted

PartQtyReasonFromFitted
OLY-RLY-48
Safety contactor relay
1RepairVanStockOct 6, 11:50 PDT