Work orders / WO-2026-01128
P1 WO-2026-01128
Corrective work order, Verified. At Pacific Highway I-5 Stop.
Response
- Priority
- P1, around-the-clock response
- Created
- Oct 6, 09:05 PDT
- Response due
- Oct 6, 13:05 PDT
- Planned
- Oct 6, 10:45 PDT
- On site
- Oct 6, 10:55 PDT
- Completed
- Oct 6, 13:10 PDT
- Verified
- Oct 6, 14:40 PDT
Who and where
- Site
- Pacific Highway I-5 Stop TW-TAC-010
- Technician
- Darnell Rhodes, Tacoma
- Contact
- +1-253-555-0316, darnell.rhodes@example.com
- High voltage cert
- Yes, valid until Oct 15, 2026
- Charge points
- TW-TAC010-CP1
Notes
PowerSwitchFailure on TW-TAC010-CP1. Main contactor does not close; no output on any connector.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0926
PowerSwitchFailure, Closed |
Critical | 46 d 6 h | – | Oct 6, 08:05 PDT | ChargePoint | No work order |
Service visits
Oct 6, 10:55 PDT to 13:10 PDT
Darnell Rhodes
- Findings
- Main contactor contacts welded; coil resistance out of range.
- Work done
- Replaced the safety contactor relay (OLY-RLY-48); torque checked on the power terminals and a full-power session completed.
- Warranty claim
- VG-WC-26-0912
Parts fitted
| Part | Qty | Reason | From | Fitted |
|---|---|---|---|---|
| OLY-RLY-48 Safety contactor relay | 1 | Repair | VanStock | Oct 6, 11:50 PDT |