Demo data. These are example records in the Tidewire model, not live data from the charging backend.
Live updates on Data as of 13:38:41 PST

Work orders / WO-2026-01124

P3 WO-2026-01124

Corrective work order, Verified. At Sixth Avenue Retail Lot.

Response

Priority
P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Sep 15, 12:27 PDT
Response due
Sep 22, 12:27 PDT
Planned
Sep 18, 12:16 PDT
On site
Sep 18, 12:26 PDT
Completed
Sep 18, 14:07 PDT
Verified
Sep 18, 15:37 PDT

Who and where

Site
Sixth Avenue Retail Lot TW-TAC-008
Technician
Ryan Delgado, Tacoma
Contact
+1-253-555-0293, ryan.delgado@example.com
High voltage cert
Yes, valid until Feb 28, 2027
Charge points
TW-TAC008-CP1

Notes

ConnectorLockFailure on TW-TAC008-CP1. Connector latch will not lock; the plug cannot be secured.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0923
ConnectorLockFailure, Closed
High 67 d 2 h–
Sep 15, 11:41 PDT ChargePoint No work order

Service visits

Sep 18, 12:26 PDT to 14:07 PDT Ryan Delgado
Findings
Latch lock actuator seized; the pin does not travel.
Work done
Replaced the connector latch lock actuator (CEV-LCK-02); locking tested with ten plug-in cycles.
Warranty claim
CEV-WC-26-0911

Parts fitted

PartQtyReasonFromFitted
CEV-LCK-02
Connector latch lock actuator
1RepairVanStockSep 18, 13:21 PDT
The connection to the dashboard was interrupted. Reload