Work orders / WO-2026-01121
P3 WO-2026-01121
Corrective work order, Verified. At Alki Waterfront Stop.
Response
- Priority
- P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Sep 2, 10:13 PDT
- Response due
- Sep 9, 10:13 PDT
- Planned
- Sep 4, 10:03 PDT
- On site
- Sep 4, 10:13 PDT
- Completed
- Sep 4, 13:27 PDT
- Verified
- Sep 4, 14:57 PDT
Who and where
- Site
- Alki Waterfront Stop TW-SEA-009
- Technician
- Danielle Ortiz, Seattle
- Contact
- +1-206-555-0218, danielle.ortiz@example.com
- High voltage cert
- Yes, valid until Jan 15, 2027
- Charge points
- TW-SEA009-CP1
Notes
ReaderFailure on TW-SEA009-CP1. Card reader does not respond; drivers cannot start a session with a card.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0920
ReaderFailure, Closed |
Medium | 80 d 5 h | – | Sep 2, 09:34 PDT | Driver | No work order |
Service visits
Sep 4, 10:13 PDT to 13:27 PDT
Danielle Ortiz
- Findings
- Reader module dead; the ribbon cable and the supply are intact.
- Work done
- Replaced the rFID card reader module (ECH-RFID-1); card and app starts tested.
Parts fitted
| Part | Qty | Reason | From | Fitted |
|---|---|---|---|---|
| ECH-RFID-1 RFID card reader module | 1 | Repair | VanStock | Sep 4, 11:08 PDT |