Work orders / WO-2026-01117

P2 WO-2026-01117

Corrective work order, Verified. At Aurora Travel Plaza.

Response

Priority
P2, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Aug 4, 10:11 PDT
Response due
Aug 6, 12:11 PDT
Planned
Aug 4, 16:01 PDT
On site
Aug 4, 16:11 PDT
Completed
Aug 4, 18:34 PDT
Verified
Aug 4, 20:04 PDT

Who and where

Site
Aurora Travel Plaza TW-SEA-017
Technician
Priya Raman, Seattle
Contact
+1-206-555-0247, priya.raman@example.com
High voltage cert
Yes, valid until Sep 30, 2026
Charge points
TW-SEA017-CP1

Notes

GroundFailure on TW-SEA017-CP1. Ground fault detected during pre-charge; sessions abort before power flows.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0915
GroundFailure, Closed
High 109 d 5 h–
Aug 4, 09:13 PDT ChargePoint No work order

Service visits

Aug 4, 16:11 PDT to 18:34 PDT Priya Raman
Findings
Insulation resistance low on the output; the ground fault interrupter trips under load.
Work done
Replaced the ground fault interrupter module (RRE-GF-020); insulation test passed and three test sessions completed.
Warranty claim
VG-WC-26-0908

Parts fitted

PartQtyReasonFromFitted
RRE-GF-020
Ground fault interrupter module
1RepairVanStockAug 4, 17:06 PDT