Demo data. These are example records in the Tidewire model, not live data from the charging backend.
Live updates on Data as of 13:38:41 PST

Work orders / WO-2026-01115

P3 WO-2026-01115

Corrective work order, Verified. At Point Defiance Park Entrance.

Response

Priority
P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Jul 22, 12:57 PDT
Response due
Jul 29, 12:57 PDT
Planned
Jul 28, 12:47 PDT
On site
Jul 28, 12:57 PDT
Completed
Jul 28, 15:03 PDT
Verified
Jul 28, 16:33 PDT

Who and where

Site
Point Defiance Park Entrance TW-TAC-004
Technician
Megan O'Connell, Tacoma
Contact
+1-253-555-0305, megan.oconnell@example.com
High voltage cert
Yes, valid until Apr 12, 2027
Charge points
TW-TAC004-CP1

Notes

OtherError on TW-TAC004-CP1. Display frozen on the start screen; sessions can only be started from the app.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0913
OtherError, Closed
Medium 122 d 2 h–
Jul 22, 12:06 PDT Driver No work order

Service visits

Jul 28, 12:57 PDT to 15:03 PDT Megan O'Connell
Findings
Display unresponsive to touch after a restart; backlight flickers.
Work done
Replaced the 7 inch touchscreen display (SDT-LCD-7); screen flow tested from start to receipt.
Warranty claim
VG-WC-26-0907

Parts fitted

PartQtyReasonFromFitted
SDT-LCD-7
7 inch touchscreen display
1RepairVanStockJul 28, 13:52 PDT