Work orders / WO-2026-01115
P3 WO-2026-01115
Corrective work order, Verified. At Point Defiance Park Entrance.
Response
- Priority
- P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Jul 22, 12:57 PDT
- Response due
- Jul 29, 12:57 PDT
- Planned
- Jul 28, 12:47 PDT
- On site
- Jul 28, 12:57 PDT
- Completed
- Jul 28, 15:03 PDT
- Verified
- Jul 28, 16:33 PDT
Who and where
- Site
- Point Defiance Park Entrance TW-TAC-004
- Technician
- Megan O'Connell, Tacoma
- Contact
- +1-253-555-0305, megan.oconnell@example.com
- High voltage cert
- Yes, valid until Apr 12, 2027
- Charge points
- TW-TAC004-CP1
Notes
OtherError on TW-TAC004-CP1. Display frozen on the start screen; sessions can only be started from the app.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0913
OtherError, Closed |
Medium | 122 d 2 h | – | Jul 22, 12:06 PDT | Driver | No work order |
Service visits
Jul 28, 12:57 PDT to 15:03 PDT
Megan O'Connell
- Findings
- Display unresponsive to touch after a restart; backlight flickers.
- Work done
- Replaced the 7 inch touchscreen display (SDT-LCD-7); screen flow tested from start to receipt.
- Warranty claim
- VG-WC-26-0907
Parts fitted
| Part | Qty | Reason | From | Fitted |
|---|---|---|---|---|
| SDT-LCD-7 7 inch touchscreen display | 1 | Repair | VanStock | Jul 28, 13:52 PDT |