P1 WO-2026-01113

Corrective work order, Verified. At Factoria I-90 Fast Stop.

Response

Priority
P1, around-the-clock response
Created
Jul 15, 09:33 PDT
Response due
Jul 15, 13:33 PDT
Planned
Jul 15, 11:29 PDT
On site
Jul 15, 11:39 PDT
Completed
Jul 15, 13:28 PDT
Verified
Jul 15, 14:58 PDT

Who and where

Site
Factoria I-90 Fast Stop TW-BEL-005
Technician
Hannah Lindqvist, Bellevue
Contact
+1-425-555-0262, hannah.lindqvist@example.com
High voltage cert
Yes, valid until May 20, 2027
Charge points
TW-BEL005-CP1

Notes

PowerSwitchFailure on TW-BEL005-CP1. Main contactor does not close; no output on any connector.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0912
PowerSwitchFailure, Closed
Critical 129 d 5 h–
Jul 15, 08:49 PDT ChargePoint No work order

Service visits

Jul 15, 11:39 PDT to 13:28 PDT Hannah Lindqvist
Findings
Main contactor contacts welded; coil resistance out of range.
Work done
Replaced the safety contactor relay (OLY-RLY-48); torque checked on the power terminals and a full-power session completed.
Warranty claim
VG-WC-26-0906

Parts fitted

PartQtyReasonFromFitted
OLY-RLY-48
Safety contactor relay
1RepairVanStockJul 15, 12:34 PDT