Work orders / WO-2026-01112
P2 WO-2026-01112
Corrective work order, Verified. At Stadium South Fast Hub.
Response
- Priority
- P2, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Jul 8, 11:19 PDT
- Response due
- Jul 10, 13:18 PDT
- Planned
- Jul 8, 14:09 PDT
- On site
- Jul 8, 14:19 PDT
- Completed
- Jul 8, 17:41 PDT
- Verified
- Jul 8, 19:11 PDT
Who and where
- Site
- Stadium South Fast Hub TW-SEA-006
- Technician
- Marcus Bennett, Seattle
- Contact
- +1-206-555-0201, marcus.bennett@example.com
- High voltage cert
- Yes, valid until Mar 31, 2027
- Charge points
- TW-SEA006-CP1
Notes
OverCurrentFailure on TW-SEA006-CP1. Output over-current trip at the start of a session.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0909
OverCurrentFailure, Closed |
High | 136 d 3 h | – | Jul 8, 10:42 PDT | ChargePoint | No work order |
| FLT-26-0910
InternalError, Closed |
Low | 136 d 3 h | – | Jul 8, 10:54 PDT | ChargePoint | No work order |
Service visits
Jul 8, 14:19 PDT to 17:41 PDT
Marcus Bennett
- Findings
- One power stage draws unbalanced current and trips the protection.
- Work done
- Replaced the breaker 2-pole 40A (RRE-BR-302); load test passed at rated current.
Parts fitted
| Part | Qty | Reason | From | Fitted |
|---|---|---|---|---|
| RRE-BR-302 Breaker 2-pole 40A | 1 | Repair | VanStock | Jul 8, 15:14 PDT |