Work orders / WO-2026-01112

P2 WO-2026-01112

Corrective work order, Verified. At Stadium South Fast Hub.

Response

Priority
P2, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Jul 8, 11:19 PDT
Response due
Jul 10, 13:18 PDT
Planned
Jul 8, 14:09 PDT
On site
Jul 8, 14:19 PDT
Completed
Jul 8, 17:41 PDT
Verified
Jul 8, 19:11 PDT

Who and where

Site
Stadium South Fast Hub TW-SEA-006
Technician
Marcus Bennett, Seattle
Contact
+1-206-555-0201, marcus.bennett@example.com
High voltage cert
Yes, valid until Mar 31, 2027
Charge points
TW-SEA006-CP1

Notes

OverCurrentFailure on TW-SEA006-CP1. Output over-current trip at the start of a session.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0909
OverCurrentFailure, Closed
High 136 d 3 h–
Jul 8, 10:42 PDT ChargePoint No work order
FLT-26-0910
InternalError, Closed
Low 136 d 3 h–
Jul 8, 10:54 PDT ChargePoint No work order

Service visits

Jul 8, 14:19 PDT to 17:41 PDT Marcus Bennett
Findings
One power stage draws unbalanced current and trips the protection.
Work done
Replaced the breaker 2-pole 40A (RRE-BR-302); load test passed at rated current.

Parts fitted

PartQtyReasonFromFitted
RRE-BR-302
Breaker 2-pole 40A
1RepairVanStockJul 8, 15:14 PDT