Work orders / WO-2026-01106

P1 WO-2026-01106

Corrective work order, Verified. At Tacoma Dome Event Hub.

Response

Priority
P1, around-the-clock response
Created
Jun 2, 09:03 PDT
Response due
Jun 2, 13:03 PDT
Planned
Jun 2, 10:54 PDT
On site
Jun 2, 11:04 PDT
Completed
Jun 2, 13:18 PDT
Verified
Jun 2, 14:48 PDT

Who and where

Site
Tacoma Dome Event Hub TW-TAC-001
Technician
Megan O'Connell, Tacoma
Contact
+1-253-555-0305, megan.oconnell@example.com
High voltage cert
Yes, valid until Apr 12, 2027
Charge points
TW-TAC001-CP1

Notes

PowerSwitchFailure on TW-TAC001-CP1. Main contactor does not close; no output on any connector.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0903
PowerSwitchFailure, Closed
Critical 172 d 6 h–
Jun 2, 08:14 PDT ChargePoint No work order

Service visits

Jun 2, 11:04 PDT to 13:18 PDT Megan O'Connell
Findings
Main contactor contacts welded; coil resistance out of range.
Work done
Replaced the main power contactor 200A (VG-CT-4011); torque checked on the power terminals and a full-power session completed.
Warranty claim
VG-WC-26-0902

Parts fitted

PartQtyReasonFromFitted
VG-CT-4011
Main power contactor 200A
1RepairVanStockJun 2, 11:59 PDT