P3 WO-2026-01104

Corrective work order, Verified. At Lincoln Plaza Chargers.

Response

Priority
P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
May 20, 10:49 PDT
Response due
May 27, 10:48 PDT
Planned
May 25, 10:38 PDT
On site
May 25, 10:48 PDT
Completed
May 25, 12:45 PDT
Verified
May 25, 14:15 PDT

Who and where

Site
Lincoln Plaza Chargers TW-BEL-002
Technician
Hannah Lindqvist, Bellevue
Contact
+1-425-555-0262, hannah.lindqvist@example.com
High voltage cert
Yes, valid until May 20, 2027
Charge points
TW-BEL002-CP1

Notes

HighTemperature on TW-BEL002-CP1. Cabinet temperature above the limit; output power derated.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0902
HighTemperature, Closed
Medium 185 d 4 h–
May 20, 10:07 PDT ChargePoint No work order

Service visits

May 25, 10:48 PDT to 12:45 PDT Hannah Lindqvist
Findings
Cooling fan not spinning and the intake filter clogged with dust.
Work done
Replaced the 24V control relay (OLY-RLY-24); cabinet temperature normal after thirty minutes at full load.
Warranty claim
VG-WC-26-0901

Parts fitted

PartQtyReasonFromFitted
OLY-RLY-24
24V control relay
1RepairVanStockMay 25, 11:43 PDT