Work orders / WO-2026-01102
P3 WO-2026-01102
Corrective work order, Verified. At Westlake Plaza Chargers.
Response
- Priority
- P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- May 12, 09:35 PDT
- Response due
- May 19, 09:35 PDT
- Planned
- May 14, 09:25 PDT
- On site
- May 14, 09:35 PDT
- Completed
- May 14, 11:15 PDT
- Verified
- May 14, 12:45 PDT
Who and where
- Site
- Westlake Plaza Chargers TW-SEA-002
- Technician
- Trevor Hanson, Seattle
- Contact
- +1-206-555-0236, trevor.hanson@example.com
- High voltage cert
- Yes, valid until Dec 5, 2026
- Charge points
- TW-SEA002-CP1
Notes
ConnectorLockFailure on TW-SEA002-CP1. Connector latch will not lock; the plug cannot be secured.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0901
ConnectorLockFailure, Closed |
High | 193 d 5 h | – | May 12, 09:00 PDT | ChargePoint | No work order |
Service visits
May 14, 09:35 PDT to 11:15 PDT
Trevor Hanson
- Findings
- Latch lock actuator seized; the pin does not travel.
- Work done
- Replaced the connector latch lock actuator (CEV-LCK-01); locking tested with ten plug-in cycles.
Parts fitted
| Part | Qty | Reason | From | Fitted |
|---|---|---|---|---|
| CEV-LCK-01 Connector latch lock actuator | 1 | Repair | VanStock | May 14, 10:30 PDT |