Demo data. These are example records in the Tidewire model, not live data from the charging backend.
Live updates on Data as of 13:38:41 PST

Work orders / WO-2026-01102

P3 WO-2026-01102

Corrective work order, Verified. At Westlake Plaza Chargers.

Response

Priority
P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
May 12, 09:35 PDT
Response due
May 19, 09:35 PDT
Planned
May 14, 09:25 PDT
On site
May 14, 09:35 PDT
Completed
May 14, 11:15 PDT
Verified
May 14, 12:45 PDT

Who and where

Site
Westlake Plaza Chargers TW-SEA-002
Technician
Trevor Hanson, Seattle
Contact
+1-206-555-0236, trevor.hanson@example.com
High voltage cert
Yes, valid until Dec 5, 2026
Charge points
TW-SEA002-CP1

Notes

ConnectorLockFailure on TW-SEA002-CP1. Connector latch will not lock; the plug cannot be secured.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0901
ConnectorLockFailure, Closed
High 193 d 5 h–
May 12, 09:00 PDT ChargePoint No work order

Service visits

May 14, 09:35 PDT to 11:15 PDT Trevor Hanson
Findings
Latch lock actuator seized; the pin does not travel.
Work done
Replaced the connector latch lock actuator (CEV-LCK-01); locking tested with ten plug-in cycles.

Parts fitted

PartQtyReasonFromFitted
CEV-LCK-01
Connector latch lock actuator
1RepairVanStockMay 14, 10:30 PDT
The connection to the dashboard was interrupted. Reload