Work orders / WO-2026-01161
P3 WO-2026-01161
Corrective work order, Planned. At West Seattle Junction Lot.
Response
- Priority
- P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Nov 17, 06:40 PST
- Response due
- Nov 23, 18:00 PST
- Planned
- Nov 18, 09:00 PST
- On site
- –
- Completed
- –
- Verified
- –
Who and where
- Site
- West Seattle Junction Lot TW-SEA-010
- Technician
- Priya Raman, Seattle
- Contact
- +1-206-555-0247, priya.raman@example.com
- High voltage cert
- Yes, valid until Sep 30, 2026
- Charge points
- TW-SEA010-CP1, TW-SEA010-CP2, TW-SEA010-CP3
Notes
Five of eight connectors out of service: cooling on CP1, contactor on CP2, latch on CP3 connector 1.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0965
HighTemperature |
High | 4 d 18 h | – | Nov 16, 19:10 PST | ChargePoint | No work order |
| FLT-26-0966
HighTemperature |
High | 4 d 18 h | – | Nov 16, 19:12 PST | ChargePoint | No work order |
| FLT-26-0967
PowerSwitchFailure |
High | 4 d 11 h | – | Nov 17, 01:40 PST | ChargePoint | No work order |
| FLT-26-0968
PowerSwitchFailure |
High | 4 d 11 h | – | Nov 17, 01:41 PST | ChargePoint | No work order |
| FLT-26-0973
ConnectorLockFailure |
High | 4 d 8 h | – | Nov 17, 05:25 PST | ChargePoint | No work order |
Service visits
No visit recorded yet.
Parts fitted
No part fitted under this work order.