Demo data. These are example records in the Tidewire model, not live data from the charging backend.
Live updates on Data as of 13:38:41 PST

Work orders / WO-2026-01140

P3 WO-2026-01140

Corrective work order, Verified. At Fremont Studio Chargers.

Response

Priority
P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Nov 4, 11:45 PST
Response due
Nov 11, 11:45 PST
Planned
Nov 6, 09:50 PST
On site
Nov 6, 10:00 PST
Completed
Nov 6, 11:30 PST
Verified
Nov 6, 13:00 PST

Who and where

Site
Fremont Studio Chargers TW-SEA-012
Technician
Marcus Bennett, Seattle
Contact
+1-206-555-0201, marcus.bennett@example.com
High voltage cert
Yes, valid until Mar 31, 2027
Charge points
TW-SEA012-CP1

Notes

EVCommunicationError on TW-SEA012-CP1. Communication with the vehicle lost during the handshake.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0939
EVCommunicationError, Closed
Low 17 d 2 h–
Nov 4, 11:00 PST Driver No work order

Service visits

Nov 6, 10:00 PST to 11:30 PST Marcus Bennett
Findings
Signal pins in the plug worn; contact intermittent when the cable is moved.
Work done
Replaced the j1772 Type 1 cable 80A 18ft (NCW-CA-J19); handshake tested with two vehicles.

Parts fitted

PartQtyReasonFromFitted
NCW-CA-J19
J1772 Type 1 cable 80A 18ft
1RepairVanStockNov 6, 10:55 PST