P3 WO-2026-01133
Corrective work order, Verified. At Capitol Hill Olive Way.
Response
- Priority
- P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Oct 20, 09:50 PDT
- Response due
- Oct 27, 09:50 PDT
- Planned
- Oct 22, 12:50 PDT
- On site
- Oct 22, 13:00 PDT
- Completed
- Oct 22, 15:10 PDT
- Verified
- Oct 22, 16:45 PDT
Who and where
- Site
- Capitol Hill Olive Way TW-SEA-013
- Technician
- Priya Raman, Seattle
- Contact
- +1-206-555-0247, priya.raman@example.com
- High voltage cert
- Yes, valid until Sep 30, 2026
- Charge points
- TW-SEA013-CP1
Notes
Contactor fault on connector 1 of TW-SEA013-CP1; connector 2 stays in service.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0930
PowerSwitchFailure, Closed |
Critical | 32 d 5 h | – | Oct 20, 09:05 PDT | ChargePoint | No work order |
Service visits
Oct 22, 13:00 PDT to 15:10 PDT
Priya Raman
- Findings
- Main contactor contacts welded; coil resistance out of range.
- Work done
- Replaced the safety contactor relay (OLY-RLY-48); torque checked on the power terminals and a full-power session completed.
Parts fitted
| Part | Qty | Reason | From | Fitted |
|---|---|---|---|---|
| OLY-RLY-48 Safety contactor relay | 1 | Repair | VanStock | Oct 22, 13:55 PDT |