Demo data. These are example records in the Tidewire model, not live data from the charging backend.
Live updates on Data as of 13:33:38 PST

Work orders / WO-2026-01151

P3 WO-2026-01151

Corrective work order, Completed. At Bellevue Library Lot.

Response

Priority
P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Nov 13, 09:35 PST
Response due
Nov 20, 09:35 PST
Planned
Nov 16, 13:00 PST
On site
Nov 16, 13:05 PST
Completed
Nov 16, 14:30 PST
Verified
–

Who and where

Site
Bellevue Library Lot TW-BEL-008
Technician
Sophie Nakamura, Bellevue
Contact
+1-425-555-0288, sophie.nakamura@example.com
High voltage cert
Yes, valid until Aug 31, 2026
Charge points
TW-BEL008-CP1

Notes

Card reader and display on TW-BEL008-CP1: drivers cannot start with a card and the screen is frozen.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0949
ReaderFailure
Medium 8 d 4 h–
Nov 13, 08:40 PST Driver No work order
FLT-26-0950
OtherError
Medium 8 d 4 h–
Nov 13, 08:55 PST Driver No work order

Service visits

Nov 16, 13:05 PST to 14:30 PST Sophie Nakamura
Findings
Reader and display both hung after a failed firmware update.
Work done
Reloaded the firmware and restarted the charge point; card start and screen flow tested from start to receipt.

Parts fitted

No part fitted under this work order.

The connection to the dashboard was interrupted. Reload