Work orders / WO-2026-01151
P3 WO-2026-01151
Corrective work order, Completed. At Bellevue Library Lot.
Response
- Priority
- P3, working-hours response (Mon–Fri 07:00–18:00 Pacific)
- Created
- Nov 13, 09:35 PST
- Response due
- Nov 20, 09:35 PST
- Planned
- Nov 16, 13:00 PST
- On site
- Nov 16, 13:05 PST
- Completed
- Nov 16, 14:30 PST
- Verified
- –
Who and where
- Site
- Bellevue Library Lot TW-BEL-008
- Technician
- Sophie Nakamura, Bellevue
- Contact
- +1-425-555-0288, sophie.nakamura@example.com
- High voltage cert
- Yes, valid until Aug 31, 2026
- Charge points
- TW-BEL008-CP1
Notes
Card reader and display on TW-BEL008-CP1: drivers cannot start with a card and the screen is frozen.
Faults answered
| Fault | Severity | Age | Charge point | Raised | Origin | Work order |
|---|---|---|---|---|---|---|
| FLT-26-0949
ReaderFailure |
Medium | 8 d 4 h | – | Nov 13, 08:40 PST | Driver | No work order |
| FLT-26-0950
OtherError |
Medium | 8 d 4 h | – | Nov 13, 08:55 PST | Driver | No work order |
Service visits
Nov 16, 13:05 PST to 14:30 PST
Sophie Nakamura
- Findings
- Reader and display both hung after a failed firmware update.
- Work done
- Reloaded the firmware and restarted the charge point; card start and screen flow tested from start to receipt.
Parts fitted
No part fitted under this work order.