P2 WO-2026-01137

Corrective work order, Verified. At Eastgate I-90 Park and Ride.

Response

Priority
P2, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Nov 2, 08:00 PST
Response due
Nov 4, 10:00 PST
Planned
Nov 5, 08:50 PST
On site
Nov 5, 09:00 PST
Completed
Nov 5, 11:40 PST
Verified
Nov 5, 13:30 PST

Who and where

Site
Eastgate I-90 Park and Ride TW-BEL-006
Technician
Sophie Nakamura, Bellevue
Contact
+1-425-555-0288, sophie.nakamura@example.com
High voltage cert
Yes, valid until Aug 31, 2026
Charge points
TW-BEL006-CP1

Notes

OverCurrentFailure on TW-BEL006-CP1. Output over-current trip at the start of a session.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0936
OverCurrentFailure, Closed
High 19 d 6 h–
Nov 2, 07:10 PST ChargePoint No work order

Service visits

Nov 5, 09:00 PST to 11:40 PST Sophie Nakamura
Findings
One power stage draws unbalanced current and trips the protection.
Work done
Reseated and secured the affected assembly, restarted the charge point; load test passed at rated current.

Parts fitted

No part fitted under this work order.