Demo data. These are example records in the Tidewire model, not live data from the charging backend.
Live updates on Data as of 13:38:41 PST

Work orders / WO-2026-01153

P2 WO-2026-01153

Corrective work order, Verified. At Convention Center Annex.

Response

Priority
P2, working-hours response (Mon–Fri 07:00–18:00 Pacific)
Created
Nov 13, 17:00 PST
Response due
Nov 18, 08:00 PST
Planned
Nov 16, 13:50 PST
On site
Nov 16, 14:00 PST
Completed
Nov 16, 16:10 PST
Verified
Nov 16, 17:40 PST

Who and where

Site
Convention Center Annex TW-SEA-003
Technician
Marcus Bennett, Seattle
Contact
+1-206-555-0201, marcus.bennett@example.com
High voltage cert
Yes, valid until Mar 31, 2027
Charge points
TW-SEA003-CP1

Notes

GroundFailure on TW-SEA003-CP1. Ground fault detected during pre-charge; sessions abort before power flows.

Faults answered

FaultSeverityAgeCharge pointRaisedOriginWork order
FLT-26-0952
GroundFailure, Closed
High 7 d 21 h–
Nov 13, 16:10 PST ChargePoint No work order

Service visits

Nov 16, 14:00 PST to 16:10 PST Marcus Bennett
Findings
Insulation resistance low on the output; the ground fault interrupter trips under load.
Work done
Reseated and secured the affected assembly, restarted the charge point; insulation test passed and three test sessions completed.

Parts fitted

No part fitted under this work order.